Phone 800-517-8431
Free Shipping over $75
HOME > FLUKE > POWER-QUALITY-ENERGY-ANALYZERS-AND-RECORDERS > POWER-QUALITY-ENERGY-ANALYZERS > 3-PHASE-POWER-QUALITY-ENERGY-ANALYZER-435IIBASIC

Fluke 435-II/BASIC

Three-Phase Power Quality and Energy Analyzer (No Probes)

Brand: Fluke
Model No: 435-II/BASIC
MPN: 4116689
Our Model No: 435IIBASIC
Condition: NEW
PDF Document Icon Data Sheet (499 KB)
435-II/BASIC

$7,599.99

Add to Cart
Request a Quote

Product Features:

  • Probes not included; for probe version, see 435-II
  • Quickly see how much energy is being wasted, in terms of real dollars
  • Easily see how motor startups are affecting motor drive performance
  • Get at-a-glance power quality health data in real-time to make better maintenance decisions
  • Capture every measurement automatically without any set-up
  • Safety rating: 600V CAT IV/1000V CAT III rated for use at service entrances
  • Fluke Connect compatible

The Fluke 435IIBASIC Three-Phase Power Quality and Energy Analyzer (No Probes) as is like a power quality insurance policy. No matter what goes wrong in your facility, you will always be prepared with the 435-II/BASIC. Equipped with advanced power quality functions and energy monetization capabilities, there is no electrical issue that this model cannot handle. Its PowerWave function captures fast RMS values and allows you to see every waveform to determine how the voltage, current and frequency values are interacting. Its Power Inverter Efficiency function measures both AC power and DC power, in and out, to monitor the efficiency of your inverters. And the 435-II/BASIC features an Energy Loss Calculator that will monetize energy waste due to poor power quality, helping you save on the energy bill.


Helps determine where energy losses occur visualize their impact on your energy bill Click for larger image

Energy Loss Calculator

Energy Loss Calculator

The 435-II/BASIC provides advanced analysis of energy usage to help you to determine where energy losses occur and to visualize their impact on the energy bill.

The 435-II/BASIC will measure these components simultaneously. The Energy Loss Calculator uses patented algoritms to calculate losses and to monetize them. The costs due to Effective W, Reactive var, Unbalance VA, Distortion VA and Neutral A are displayed per Hour. The total costs are displayed per year which gives you an impression of possible savings on a yearly basis. Four different rates can be set (price per kWh as a function of period of day). The length (meters or feet) and diameter (square millimeter or AWG/American Wire Gauge) of the cables between service entrance and the load can be set manually. In AUTO mode a loss of 3% due to wire resistance is assumed, which is normal for an average distribution system.


ASystem Monitor displays a Bar graph screen Click for larger image

Advanced Power Quality Health

Advanced Power Quality Health

The MONITOR mode delivers a dashboard display of rms voltage, harmonics, flicker, interruptions, rapid voltage changes, swells, unbalance, frequency and mains signaling.

The dashboard is updated live, showing compliance of each parameter to EN50160 limits or your own limits. Color-coded bars clearly show which parameters are inside (pass) or outside (fail) limits. During a monitor session, you can easily drill down to more detail of any parameter to view and capture its trend for a report.

Power Inverter Efficiency

Power Inverter Efficiency measures the efficiency and amount of energy being delivered by inverters that convert single phase DC into a single or three phase AC. Solar generation systems usually include an inverter that takes the DC energy from the solar cells and converts it to useful AC power. Inverters can lose performance over time and need to be checked. By comparing the input power with the output power you can determine the system efficiency. The 435-II/BASIC can measure the efficiency of such inverters by simultaneously measuring the dc and ac power of a system to determine how much power is lost in the conversion process.

Unified Power Measurement

Previously, only experts could calculate how much energy was wasted due to power quality issues; utilities could calculate the cost, but the required measurement process was beyond the reach of average electricians. With the patented Unified Power function of the 435-II/BASIC, you can use one handheld tool to determine how much power is being wasted, and calculate exactly what the extra consumption costs. The Unified Power Measurement System measures Parameters of Classical Power (Steinmetz 1897) and IEEE 1459-2000; Detailed Loss Analysis; and Unbalance Analysis. These UPM calculations are used to quantify the fiscal cost of energy loss caused by power quality issues. Along with other facility-specific information, the calculations are computed by an Energy Loss Calculator that ultimately determines how much money a facility loses due to wasted energy.

UPM gives a more comprehensive breakdown of the energy consumed in a plant. In addition to measuring reactive power (caused by poor power factor), UPM also measures the energy waste caused by unbalance - the effect of unevenly loading each phase into three-phase systems. Unbalance can often be corrected by reconnecting loads on different phases to ensure the current drawn on each phase is as equal as possible. Unbalance can also be corrected by installing an unbalance reactance device (or filter), that will minimize the effects. Correcting unbalance should be basic to good housekeeping in the facility, as unbalance problems can cause motor failure or shorten equipment life expectancy. Unbalance also wastes energy.

UPM also provides details of the energy wasted in your facility due to the presence of harmonics. Harmonics may be present in your facility due to the loads you operate or may be caused by loads in adjacent facilities. The presence of harmonics in your facility can lead to overheating transformers and conductors; nuisance tripping of circuit breakers; and early failures of electrical equipment. Quantifying the cost of wasted energy due to the presence of harmonics simplifies the return-on-investment calculations needed to justify purchasing harmonic filters. By installing a harmonic filter the ill effects of harmonics can be reduced and energy waste eliminated, resulting in lower operational costs and more reliable operation.


Volts/Amps/Hertz Trend display Click for larger image

AutoTrend

AutoTrend

With a unique AutoTrend feature you can get fast insight into changes over time. Every displayed reading is automatically and continuously recorded without seting up threshold levels or manually starting the process. You can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.

The Analyzer functions as a high resolution 8 channel scope recorder Click for larger image

PowerWave Data Capture

PowerWave Data Capture

PowerWave records high resolution waveforms during a time span of several minutes. This allows you to monitor the influence of sudden load changes on voltage and current waveforms. For example, large voltage changes may indicate a weak power distribution system.

In this measuring mode, the 435-II/BASIC functions as an 8 channel scope recorder that records high resolution waveforms in a single shot acquisition. The function records half cycle rms values on 8 channels, frequency and instantaneous power (Vrms 1/2, Arms 1/2, W, Hz and scope waveforms for Voltage, Amps, Watts).

  • 1 - Power Adapter (BC430)
  • 1 - International Plug Adapter Set
  • 1 - Li-ion Battery (BP290)
  • 1 - Test Lead and Alligator Clip Set (TL430)
  • 1 - Color Coding Clips and Regional Decals (WC100)
  • 1 - 8 GB SD card
  • 1 - A-B Mini USB Cable
  • 1 - Soft Carrying Case (C1740)
  • 1 - User Manual and PowerLog Software (CD)
Carrying Cases
Model Description Buy Now Price
C437-II Fluke C437-II Hard Carrying Case with Rollers for 430-II Series Add to Cart
($699.99)
Sale $629.99
C1740 Fluke C1740 Soft Carrying Case with Buckle for Power Quality Analyzers Add to Cart
($299.99)
Sale $269.99
HH290 Fluke HH290 Hanging Hook for 190-II Series Add to Cart
($89.99)
Sale $71.95

Only 3 left in stock
Current Clamps
Model Description Buy Now Price
I400S Fluke I400S AC Current Clamp/BNC, 0.5A-4000A AC Switchable Add to Cart
($289.99)
Sale $260.99

Only 2 left in stock
Modules
Model Description Buy Now Price
GPS430-II Fluke GPS430-II GPS Time Synchronization Module for 430-II Series Add to Cart

$1,599.99

Power Supplies
Model Description Buy Now Price
BP291 Fluke BP291 High Capacity Li-Ion Battery for 190-II Series, 4800 mAH Add to Cart
($349.99)
Sale $314.99

Only 3 left in stock
Test Leads, Probes and Clips
Model Description Buy Now Price
I5SPQ3 Fluke I5SPQ3 AC Current Clamps for 430-II Series, 5A AC Add to Cart

$1,299.99


Only 1 left in stock
WC100 Fluke WC100 32-Piece Color Localization Set (8 Colors) Add to Cart
($25.99)
Sale $22.61
Upgrades
Model Description Buy Now Price
430-II/MA Fluke 430-II/MA Motor Analyzer Upgrade Kit for 430-II Series Add to Cart

$2,499.99

Fluke Careplans
Model Description Buy Now Price
G3P-GROUP4 Fluke G3P-GROUP4 5-Year Gold CarePlan for 196C, 199C, 434, 435, 724, 725, 726, 700BCW, 741 and 743 Add to Cart

$1,099.99

S3P-GROUP4 Fluke S3P-GROUP4 3-5-Year Silver CarePlan for 196C, 199C, 434, 435, 724, 725, 726, 700BCW, 741, 743 Add to Cart
($374.99)
Sale $125.00
Fluke 430 Series II
Fluke 430 Series II
Logging Capture and Sample Rate On a Fluke 435 Series II
Logging Capture and Sample Rate
on a Fluke Series 435 II
Fluke 430 Series II
Fluke Series 430 II
How To Check For Dips And Swells Using The Fluke 435
How to Check for Dips and Swells
Using the Fluke Series 435 II
How To Connect Using The Phasor Diagram On A Fluke 435
How to Connect Using the Phasor Diagram
on a Fluke Series 435 II
How To Perform A Logger Set-Up On The Fluke 435 II
How to Perform a Logger Set-Up
on the Fluke Series 435 II
How To Perform A Transient Capture On The Fluke 435
How to Perform a Transient Capture
on the Fluke Series 435 II
How To Perform A Trend Configuration On The Fluke 435
How to Perform a Trend Configuration
on the Fluke Series 435 II
How To Transfer Data From The Fluke 435 To Power Log
How to Transfer Data
from the Fluke Series 435 II
How To Use A Harmonics Test In A 435 Power Quality Analyzer
How to Use a Harmonics Test
in a Fluke Series 435 II
Data Sheet: PDF Document Icon (499 KB)
Manual: PDF Document Icon (2.65 MB)
Brochure PDF Document Icon (1.25 MB)
Could you make better operational and maintenance decisions? PDF Document Icon (279 KB)
WiFi download from the Fluke 430 Series-II Analyzers PDF Document Icon (192 KB)
The costs of poor power quality PDF Document Icon (681 KB)
↑ Back to Top